99视频在线精品最新免费观看_天天夜夜草草久久亚洲香蕉_最新国产清清在线视频_黄色一级片大美女_日韩中文字幕V亚洲中文字幕_六月婷婷国产精品综合_亚洲无码在线播_午夜香港三级A三级三点_日本有码中文字幕欧美日韩_影音先锋人妻啪啪aV资源网

CN EN
QQ
+86-(0)15021555579
qrCode

Corrugated flame arrester



Location:Products >> Flame arrester and breathing valve >> Corrugated flame arrester
Model: ZGB-1
Nominal diameter: DN50 ~ 300mm (2 "~ 12")
Nominal pressure: PN0.6 ~ 5.0MPa
Working temperature: ≤480 ℃ The
Main material: carbon steel WCB, stainless steel 304,316
Applicable medium: A type, oil, liquefied hydroxide type, kerosene, Diesel oil, a stupid, crude oil
Connection: flange connection (II) thread connection (III) male thread (IV)
Design standards: GB5908-86, GB1347-92
Flange standard: HG 20592-97, ANSI B 1.6, GB HGJ SH JB
Product details

ZGB-1 corrugated flame arrester Overview:
This product is widely used in oil storage tanks, is to prevent accidental fire invade the tank, to prevent accidents, is the ideal product for tank fire. 

ZGB-1 Corrugated flame arrester performance and features:

• The flame arrester has the advantages of reasonable structure, light weight, corrosion resistance and explosion-proof performance, and can withstand fire for 13 times in a row with a subsonic flame test. 
Flame arrester easy to repair, easy to install, do not check when removing the breathing valve. Resistance to burning qualified, resistant to burning test 1 hour without tempering. 
• The flame arrester core is stainless steel, corrosion-resistant and easy to clean. Shell hydraulic test qualified.

ZGB-1 corrugated flame arrester Scope:
The flame arrester is suitable for pipes, flash point of less than 28 ℃ Class A, oil, hydrogenated liquefied and flash point of less than 60 ℃ of kerosene, diesel, a stupid, crude oil And so on, can be used with the respiratory valve supporting the use, but also can be used alone, within the floating roof tank vent, gas tank on the ground floor gas tank. 
 
Corrugated flame arrester repair and maintenance:
In order to ensure the performance of flame arrester to achieve the purpose of safe use, flame arresters should be regularly checked and maintained. 
 • Flame arresters are inspected semi-annually to check if the fire barrier core is clogged, deformed, etched. 
 • It is found that the plugged flame barrier core should be cleaned to ensure that each hole in the core is clear and that the fire barrier should be replaced for deformation and corrosion. 
 • When reinstalling the flame retardant core, ensure that the joint surface is tight and leakproof.

Corrugated flame arrester parts material:

Body material Carbon steel WCB, stainless steel 304,316
Fire retardant core material Stainless steel explosion-proof corrugated plate
Sealing material Asbestos rubber, PTFE PTFE
Ambient temperature ℃ ≤480
Nominal pressure (MPa) 0.6 ~ 5.0
Explosion-proof level BS5501: Ⅱ A, Ⅱ B, Ⅱ C